AIRTEC - Series KN-05 NAMUR, electrically operated

คุณสมบัติสินค้า:

SKU : Series KN-05

Series KN-05, KN-55 NAMUR, electrically operated 3/2-way, 5/2-way and 5/3-way, nominal size 6 mm, G1/4

Share

หมวดหมู่ : All

แบรนด์ : AIRTEC

Share

Standardized valves | Series KN-05, KN-55

NAMUR valves and the ISO 5599/1Valve Series are the centerpiece of AIRTEC’s range of standardized valves. Outstanding quality and years of experience with NAMUR components has made AIRTEC into one of the world’s leading providers of standardized electric valves and accessories, as well as pneumatic NAMUR-valves.

 

Series KN-05, KN-55

NAMUR, electrically operated
3/2-way, 5/2-way and 5/3-way, nominal size 6 mm, G1/4

 

Technical details

ConnectionG1/4, Namur
Nominal size6 mm
Temperature range-10°C ... +70°C
MediumFiltered, oil-free and dried compressed air according to ISO 8573-1:2010, Class 7:2:4, instrument air, free of aggressive additives. Alternatively the pressure dew point must be at least 10°C below lowest occurring ambient temperature.
MaterialsBody: Al (anodized), plastic, seals: NBR, inner parts: Al, steel and plastic
ProtectionIP 65 according to EN 60529
Valves in accordance with 2014/34/EU (ATEX) available. (Chapter 13)

Electrically operated spool valve. The manual override is detent and is operated by screw driver. The model KN-55 has a coil with enhanced humitidy resistance and a additional gasket at the coil. The location pin, screws and seals are included.

3/2-way-valves5/2- and 5/3-way-valves
KN-05-310-HN-xxx
KN-55-310-HN-xxx
3/2-way, single solenoid, air spring
return, NC
KN-05-510-HN-xxx
KN-55-510-HN-xxx
5/2-way, single solenoid, air spring
return
KN-05-311-HN-xxx
KN-55-311-HN-xxx
3/2-way, single solenoid, mechanical
spring return, NC
KN-05-511-HN-xxx
KN-55-511-HN-xxx
5/2-way, single solenoid, mechanical
spring return
 KN-05-520-HN-xxx
KN-55-520-HN-xxx
5/2-way, double solenoid
KN-05-530-HN-xxx
KN-55-530-HN-xxx
5/3-way, center position closed
KN-05-533-HN-xxx
KN-55-533-HN-xxx
5/3-way, center position exhausted

Electrical options

Nominal voltagePower consumptionSpecificsPlug connection*1-xxx
KN-05KN-55
12 V DC4.2 W
Form B industrial norm-441-741
12 V DC2.2 Wmax. 8 barForm B industrial norm-461-761
24 V DC4.2 W
Form B industrial norm-442-742
24 V DC4.8 W
M 12-O42-
24 V DC2.2 Wmax. 8 barForm B industrial norm-462-762
24 V DC2.5 Wmax. 8 barM 12-O62-
24 V DC7/4 VA Form B industrial norm-452-752
115 V AC7/4 VA Form B industrial norm-456-756
230 V AC7/4 VA Form B industrial norm-457-757

Series KN-05, KN-55

NAMUR, electrically operated
3/2-way, 5/2-way and 5/3-way, nominal size 6 mm, G1/4

Technical data

Model-no.:KN-05-310
KN-55-310
KN-05-311
KN-55-311
KN-05-510
KN-55-510
KN-05-511
KN-55-511
KN-05-520
KN-55-520
KN-05-530
KN-55-530
KN-05-533
KN-55-533
Operating pressure* (bar)3...103...103...103...102...103...103...10
Pilot pressure* (bar)3...103...103...103...102...103...103...10
Flow rate (Nl/min)780780900800900680680
Response time (ms)on:     16on:     13on:     16on:     16on:     14on:     14on:     14
at 6 baroff:     18off:     16off:     17off:     18off:     14off:     16off:     16
Weight (kg)0.3200.3200.3200.3200.4400.4400.440

Dimensions Series KN-05, KN-55

NAMUR, electrically operated
3/2-way, 5/2-way and 5/3-way, nominal size 6 mm, G1/4

KMN-0-045-3-3110x--HHNN., M KNO--5054--3311x0--HHNN
KMN-0-045-3-5110x--HHNN., M KNO--5054--5311x0--HHNNKN-05-520-HN, KN-55-520-HN, KN-05-53x-HN, KN-55-53x-HN
1 = pressure inlet
2,4 = outlets
3,5 = exhausts
Plug socket (not included in scope of delivery) can be repositioned by
180°.
Solenoid coil can be repositioned by 4 x 90°.

Plug sockets

Form B according to DIN EN 175301-803

Overall width22 mm
Contact distance10 mm
Contacts2P + E
Protection For use with seriesIP 65 according to EN 60529 requires a flat gasket

 

Model-no.:28-ST-01-G
Voltage (AC/DC)0 - 250 V
Status indicatorno
Protective circuitno
Connecting cablewithout
Wire cross sectionmax. 1.5 mm²
Ø Connecting cable6 - 8 mm

 

Form B industrial norm

Overall width22 mm

Contact distance

11 mm
Contacts2P + E
ProtectionIP 65 according to EN 60529 requires a flat gasket
For use with seriesM-04, M-05, M-07, M-22, KM-09, KM-10, MS-18, KN-05,MN-06, MI-01, MI-02, MI-03

 

Model-no.:28-ST-0128-ST-04-11228-ST-04-12728-ST-06-11228-ST-06-12728-ST-06-K3-112*28-ST-06-K3-127*
Voltage (AC/DC)0 - 250 V10 - 50 V70 - 250 V24 V230 V24 V230 V
Status indicatornoyesyesyesyesyesyes
Protective circuitnononoyes (varistor)yes (varistor)yes (varistor)yes (varistor)
Connecting cablewithoutwithoutwithoutwithoutwithout3 m3 m
Wire cross sectionmax. 1.5 mm²max. 1.5 mm²max. 1.5 mm²max. 1.5 mm²max. 1.5 mm²3 x 0.75 mm²3 x 0.75 mm²
Ø Connecting cable6 - 8 mm6 - 8 mm6 - 8 mm6 - 8 mm6 - 8 mm  

 

Dimensions

Form B according to DIN EN 175301-803Form B industrial norm

 

อ้างอิง : airtec.de

สอบถามข้อมูลเพิ่มเติม AIRTEC - Series KN-05 NAMUR

โทร: 02-384-6060  |  ไลน์: @flutech.co.th  | อีเมล: sales@flutech.co.th
 
Powered by MakeWebEasy.com
เว็บไซต์นี้มีการใช้งานคุกกี้ เพื่อเพิ่มประสิทธิภาพและประสบการณ์ที่ดีในการใช้งานเว็บไซต์ของท่าน ท่านสามารถอ่านรายละเอียดเพิ่มเติมได้ที่ นโยบายความเป็นส่วนตัว  และ  นโยบายคุกกี้