Last updated: 20 พ.ค. 2562 | 1806 จำนวนผู้เข้าชม |
Plunger valve 2/2 way direct-acting
Valve 6013 is a direct-acting plunger valve. The stopper and plunger guide tube are welded together to enhance pressure resistance and leak-tightness. Various seal material combinations are available depending on the application. A Bürkert-specific flange design (SFB) enables space-saving arrangement of valves on a manifold. The coils are moulded with polyamide or with chemically resistant epoxy. Pulse coils and 'Kick and Drop' electronics are available for overexcitation (plug 2511) for the reduction of electrical power consumption during operation. Optional manual actuation enables quick commissioning and easy maintenance. In combination with a plug in accordance with DIN EN 17301-803 Form A, the valves satisfy protection class IP65. Stainless steel valves satisfy NEMA 4X.
Direct-acting and compact valve up to diameter of DN 6.0
Vibration-proof, bolted coil system
Increased leak-tightness with welded plunger guide tube
Explosion proof versions
Energy-saving pulse versions
Circuit Function A
: 2/2 way direct-acting solenoid valve, normally closed
Circuit Function B
: 2/2 way direct-acting solenoid valve, normally open
Technical data | |
Body material Type 6013 | Brass, stainless steel 1.4305 |
Seal material | FKM, PTFE/Graphite (EPDM on request) |
Analysis version Type 6013 A | Silicon, oil and fat free version Tightness <10-4 mbar l/s |
Limit value for risidual carbon Type 6013 A | <0.2 mg/dm² |
Medium Type 6013 | • Technical vacuum • Neutral gases and liquids (e.g. compressed air, water, hydraulic oil) • Neutral medium, which does not attack the body and seal materials (see chemical resistance chart) |
Medium temperature FKM PTFE/Graphite FKM, Circuit function B | -10 to +100 °C (PA coil) till 120 °C (Epoxy coil) -40 to +180 °C (see chemical resistance chart) -10 to 100 °C (AC) -10 to 120 °C (DC) |
Ambient temperature | Max. +55 °C |
Viscosity | Max. 21 mm²/s |
Port connection Type 6013 Type 6013 A | G ⅛, G ¼, G ⅜, sub-base (SFB) G ⅛, G ¼ |
Operating voltage Type 6013 Type 6013 A | 24 V DC, 24 V/50 Hz, 230 V/50 Hz 24 V DC, 230 V/50 Hz (other voltages on request) |
Voltage tolerance | ±10% |
Duty cycle/single valve With block assembly on manifold | 100% continuous rating Intermittent operation 60% (30 min) or with 5 W coil on request |
Electrical connection | Tag connector acc. to DIN EN 175301-803 Form A (previously DIN 43650) for cable plug Type 2508 (see accessories) ATEX/IECEx version with 3 m moulded cable |
Installation | As required, preferably with actuator upright |
Assembly | No oils, fats or silicone to be used during installation |
Protection class | IP65 with cable plug, ATEX/IECEx junction box version and cable connection version |
Coil insulation class | Polyamide class B Epoxy class H |